Current October update · English technical context

品位吸引关注;回收率决定其价值是否成立。

The combined assay compilation covers 879 holes and 7,468.8 assayed metres at the 25 September 2026 cutoff. It includes prior results and complete or partial assay coverage; it is not all-new drilling or gross physical drilling.

MAV_RC_0063 returned 30 metres from surface at 1,853 ppm MREO. Selected cumulative auger profiles include 8 metres at 2,194 ppm MREO in MAV_AD_0691 and 11 metres at 2,179 ppm MREO in MAV_AD_0639.

Reporting of the SGS bench-scale results is the next milestone, after results reconciliation and technical review. No numerical results from this programme are disclosed here. An optimised flowsheet and commercial recovery have not been established; timing and outcomes are not guaranteed.

Older translated project chapters are retained below as dated context, not as the October update. Updated technical translation is not asserted.

Dated translated context · issued-source chapter through 8 September 2026

Minas Americas · 冶金与产品路径

品位吸引关注;回收率决定其价值是否成立。

Minas Americas 已报告原矿品位化验结果和初步诊断性溶液响应。下一阶段将测定代表性提取率、杂质行为、质量平衡及潜在产品路线。

诊断性筛选测量了什么

从选定的黏土样本到溶液分析。

筛选测量了初始浸出液中的稀土浓度,并为有代表性的回收工作设定了起点。

初步实验室诊断 · 精选 2025 年矿段
SGS ICM694 0.5 M (NH₄)₂SO₄ 初始 pH 值 4.00 接触 30 分钟 单一诊断筛选
  1. 选定制成的黏土样本 层状黏土颗粒,颗粒表面显示稀土离子。
    01固体投料
    选定矿段样品

    经制备和筛分的实验室物料。总原矿化验值是对固体样品的另一项独立测量。

    原矿化验矩阵 · 固体中 ppm
  2. 单一温和的实验室接触 含有黏土和硫酸铵溶液的实验室容器,稀土离子显示进入液体。
    02定义条件
    单次实验室接触

    铵离子在一个说明的试验条件下与一些表面附着的稀土离子进行交换。

    诊断测试 · 并非工厂流程图
  3. 从固体残渣中分离出的初始浸出液 试验分离出用于分析的液态主浸出液和完全质量平衡所需的固体残渣。
    03液体产出
    初始浸出液

    接触后的液体作为 PLS 收集。它是测试溶液,而不是产品。

    固体残渣 · 完整质量平衡所需
  4. 初始浸出液的元素分析 分析读出记录了初始浸出液中的稀土和其他元素浓度。
    04测量结果
    ICP-MS 溶液分析

    在 PLS 中测得的元素以氧化物当量 DREO 总量表示,其中包括 MREO 子集。

    诊断结果 · mg/kg PLS
筛选支持什么

在所述条件下,部分稀土元素进入溶液,为精选测试样品中的离子吸附行为提供支持。

不能据此证明什么

提取率或回收率、代表性、完整质量平衡、商业流程图、产品规格或项目经济性。

精选诊断性筛选;未经优化。DREO = 可解吸稀土氧化物。MREO = Nd、Pr、Dy 和 Tb 的氧化物。来源:SGS 证书 GQ2509212 及 2025 年 10 月 21 日技术披露。溶液浓度不等于回收率。

精选浅部诊断性浸出结果

Figure 2 · issued English-source graphic and technical context · 6 October 2026

Magnet and heavy rare earths gain share in solution. Four selected 2025 trench intervals and one later auger interval compare original-sample and dissolved-mix MREO and HREO shares. HREO share more than doubles in all five selected diagnostic tests. Composition comparison, not extraction recovery.

Magnet and heavy rare earths gain share in solution. Figure 2 from the 6 October 2026 release: four selected 2025 trench intervals, plus a later auger interval. HREO represented 6.6–12.1% of the dissolved rare-earth mix, compared with 3.0–4.1% in the original samples.

These are composition shares, not extraction recovery or an increase in absolute solution concentration. MREO and HREO overlap through DyTb and must not be added. Selected diagnostic tests are separate from the current SGS bench programme and do not establish an optimised flowsheet or project-wide recovery.

Read the graphic values as a table
Figure 2 · original sample (share of TREO) and dissolved mix (share of DREO)
Selected intervalMREO · originalMREO · dissolvedHREO · originalHREO · dissolvedHREO share multiple
PT-34 · 0–1 m23.7%41.9%3.3%9.3%2.81×
PT-34 · 1–2 m25.3%41.6%4.1%10.9%2.68×
PT-36 · 0–1 m22.2%41.6%3.0%6.6%2.20×
PT-42 · 0–1 m23.8%43.6%3.9%8.2%2.09×
MAV_AD_0002 · 2–3 m (later auger)26.3%48.1%3.6%12.1%3.34×

Later auger interval DyTb share: 0.94% → 2.08%. Shares and multiples use unrounded oxide totals; below-detection values use half the detection limit. SGS ICM694: 0.5 M ammonium sulphate, initial pH 4, 30 minutes. MREO comprises Nd, Pr, Dy and Tb oxides; HREO comprises Y, Dy, Tb, Ho, Er, Tm, Yb and Lu oxides. The graphic panels use different scales.

Diagnostic composition · October source basis

These are the five selected historical diagnostic intervals, not the seven geological samples in the separate SGS bench-scale programme. Values describe desorbed oxide equivalents on the laboratory mg/kg reporting basis—not increased absolute solution concentration or recovery.

October release Table 3 · selected diagnostic intervals · shares use unrounded source totals
IntervalMREO (mg/kg)DREO (mg/kg)MREO share of DREO
PT-34 · 0–1 m16138441.9%
PT-34 · 1–2 m24057841.6%
PT-36 · 0–1 m27866741.6%
PT-42 · 0–1 m16738343.6%
MAV_AD_0002 · 2–3 m23749248.1%

The October source reports PT-34 0–1 m DREO using half detection limits; the reconciled figure is shown above, while the earlier graphic remains unchanged in the dated archive below. MREO and HREO overlap through DyTb and must not be added. Composition is not extraction recovery or commercial process performance.

Historical diagnostic graphic and technical plate · original reporting basis

This is the unchanged earlier illustration, not the October source table or the new SGS bench results. Its original reporting basis must be read in that dated context.

Magnet-Rich in Solution. Five selected shallow SGS diagnostic intervals compared on one common zero-to-700 milligram-per-kilogram scale, with magnet rare-earth oxides highlighted within DREO in solution.
Five selected shallow intervals were tested using the same SGS ICM694 diagnostic method: 0.5 molar ammonium sulphate, nominal pH 4, for 30 minutes. PT-34 from zero to one metre returned 161 milligrams per kilogram MREO in 383 milligrams per kilogram DREO, a 41.9 percent magnet share. PT-34 from one to two metres returned 240 milligrams per kilogram MREO in 578 milligrams per kilogram DREO, a 41.6 percent magnet share. These are two consecutive one-metre intervals from surface. PT-36 from zero to one metre returned 278 milligrams per kilogram MREO in 667 milligrams per kilogram DREO, a 41.6 percent magnet share. PT-42 from zero to one metre returned 167 milligrams per kilogram MREO in 383 milligrams per kilogram DREO, a 43.6 percent magnet share. A later shallow-auger test, MAV_AD_0002 from two to three metres, returned 237 milligrams per kilogram MREO in 492 milligrams per kilogram DREO, a 48.1 percent magnet share. Across the five selected intervals, MREO represented 22.2 to 26.3 percent of TREO in the original samples and 41.6 to 48.1 percent of DREO in solution. This is a composition comparison, not recovery. Each displayed value is a solution concentration, not a recovery percentage. DREO means total desorbable rare-earth oxides expressed as oxide equivalents; MREO comprises the neodymium, praseodymium, dysprosium and terbium oxides. Values are on the laboratory reporting basis. The tests were diagnostic, not optimised, and the results are selected.
Inspect the five selected results and common scale at full resolution.The same selected-result data is provided in accessible HTML in the figure description on this page.
Accessible data transcript (HTML)

Five selected shallow intervals tested using SGS ICM694: 0.5 M ammonium sulphate, nominal pH 4 and 30 minutes.

Magnet rare-earth oxides within DREO in solution
IntervalMREO in solutionDREO in solutionMREO share of DREO
PT-34 · 0-1 m161 mg/kg383 mg/kg41.9%
PT-34 · 1-2 m240 mg/kg578 mg/kg41.6%
PT-36 · 0-1 m278 mg/kg667 mg/kg41.6%
PT-42 · 0-1 m167 mg/kg383 mg/kg43.6%
MAV_AD_0002 · 2-3 m237 mg/kg492 mg/kg48.1%

Selected diagnostic results, not optimised or representative recovery tests. Values are solution concentrations, not recovery percentages. MREO comprises Nd, Pr, Dy and Tb oxides; DREO is expressed on an oxide-equivalent basis.

从化验到可计价性

从岩石到收入的五种不同度量法。

每个步骤回答不同的问题:从物料中含有什么,到能够回收、制成并销售什么。

  1. 01

    原矿品位

    原始固体样品在加工前所含的成分。6 月钻探结果属于原矿品位化验。

  2. 02

    诊断性溶液结果

    在一项条件明确的实验室测试中进入溶液的部分。精选 2025 年测试即处于这一阶段。

  3. 03

    提取率或解吸率

    原始元素总量中转移至溶液的实测比例,并以样品质量、溶液体积和质量平衡为依据。

  4. 04

    全流程回收率

    经过各工艺阶段后进入既定产品的比例,包括损失和循环物料流。

  5. 05

    可计价回收率

    在考虑产品规格、杂质和商业扣减后,客户愿意支付对价的部分。

如果缺少原始样品质量、溶液体积、固液比和完整质量平衡,就不能用固体原矿化验值除以溶液中以 mg/kg 报告的浓度来计算回收率。

Dated translated context · issued-source chapter through 8 September 2026

流程

建立完整工艺流程图。

代表性工作将核对给料、溶液、残渣、损失和选定产品路线中的稀土与杂质质量平衡。

实验室不同组分的概念示意图,并非测试结果。图中不表示数量,也不能据此确定回收率。
制备后的样品溶液固体残渣

实验室不同组分的概念示意图,并非测试结果。图中不表示数量,也不能据此确定回收率。

  1. 01
    已报告原矿品位

    给料

    利用钻探记录和矿物学制备代表性工艺组合样。

  2. 02
    已报告精选筛选结果

    初始浸出液

    在一次条件明确的硫酸铵试验后测得稀土浓度;这一响应可用于设计代表性回收率测试。

  3. 03
    所需质量平衡

    残渣及其他物料流

    完整质量平衡必须说明稀土、铀、钍及其他杂质分别进入何处。

  4. 04
    待定

    潜在产品

    选择通往中间产品、分离产品或下游合作伙伴接口的最佳路线。

溶液中的稀土;三个精选结果中的铀均低于实验室检出限。图中列示 PT-36、PT-34 和 PT-42 的准确铀、钍浓度。
在三个精选 2025 年初始浸出液结果中,铀在每项结果中均低于 0.04 mg/kg;钍分别报告为 2.59 mg/kg、低于 0.20 mg/kg 和 2.92 mg/kg。 精选矿段为:PT-36,0–1 m,667 mg/kg DREO,铀 <0.04 mg/kg,钍 2.59 mg/kg;PT-34,1–2 m,578 mg/kg DREO,铀 <0.04 mg/kg,钍 <0.20 mg/kg;PT-42,0–1 m,383 mg/kg DREO,铀 <0.04 mg/kg,钍 2.92 mg/kg。SGS Geosol 采用 ICM694 方法:0.5 mol/L 硫酸铵、初始 pH 4、30 分钟,并使用 ICP-OES 与 ICP-MS 测量。DREO 以氧化物当量表示;铀和钍以元素浓度报告。“<”表示低于所述实验室检出限,而非零。 这些是精选诊断性溶液结果,并非资源量平均值或具有代表性的放射性数据集。相关浓度不能表征给料、残渣、水、工作场所、潜在产品或整个矿权范围内的铀或钍,也不能确立转移、回收率、质量平衡、总放射性、产品规格、环境安全性或商业表现。
以完整分辨率查看全部三个精选 U 和 Th 结果。下方紧接着提供内容等同的无障碍 HTML 数据文本。
无障碍数据文本(HTML)

精选 SGS ICM694 初始浸出液结果:0.5 M 硫酸铵、初始 pH 4、30 分钟。

三个精选矿段的铀、钍及 DREO 结果
矿段PLS 中的 DREO铀钍
PT-36 · 0-1 m667 mg/kg<0.04 mg/kg U2.59 mg/kg Th
PT-34 · 1-2 m578 mg/kg<0.04 mg/kg U<0.20 mg/kg Th
PT-42 · 0-1 m383 mg/kg<0.04 mg/kg U2.92 mg/kg Th

小于号表示低于 SGS 实验室检出限,并不等于零。DREO 以氧化物当量表示;U 和 Th 为元素浓度。 这些是精选诊断性溶液结果,并非资源量平均值或具有代表性的放射性数据集。相关浓度不能表征给料、残渣、水、工作场所、潜在产品或整个矿权范围内的铀或钍,也不能确立转移、回收率、质量平衡、总放射性、产品规格、环境安全性或商业表现。

辐射证据

建立完整的放射性特征全貌。

在三个精选 2025 年初始浸出液结果中,铀在每项结果中均低于 0.04 mg/kg;钍分别报告为 2.59 mg/kg、低于 0.20 mg/kg 和 2.92 mg/kg。

下一步是在完整质量平衡和适当放射性测量的基础上,对代表性给料—溶液—残渣—产品进行表征。

产品路径

首先定义一个产品,然后测试一个客户是否可以使用它。

具有代表性的矿物学,元素逐项提取,杂质行为和质量平衡必须先于可经受审查的产品概念。

只有完成这些工作,Magnes 及潜在合作伙伴才能评估净化、分离、认证、可实现售价,以及资本和运营影响。

讨论相关能力

投资逻辑

参见冶金如何改变投资逻辑。

代表性回收率、杂质情况和产品定义将决定地质结果中有多少能够转化为商业价值。

看看有什么变化