Current October update · English technical context

품위는 관심을 끌지만, 의미를 결정하는 것은 회수율입니다.

The combined assay compilation covers 879 holes and 7,468.8 assayed metres at the 25 September 2026 cutoff. It includes prior results and complete or partial assay coverage; it is not all-new drilling or gross physical drilling.

MAV_RC_0063 returned 30 metres from surface at 1,853 ppm MREO. Selected cumulative auger profiles include 8 metres at 2,194 ppm MREO in MAV_AD_0691 and 11 metres at 2,179 ppm MREO in MAV_AD_0639.

Reporting of the SGS bench-scale results is the next milestone, after results reconciliation and technical review. No numerical results from this programme are disclosed here. An optimised flowsheet and commercial recovery have not been established; timing and outcomes are not guaranteed.

Older translated project chapters are retained below as dated context, not as the October update. Updated technical translation is not asserted.

Dated translated context · issued-source chapter through 8 September 2026

Minas Americas · 야금 및 제품화 경로

품위는 관심을 끌지만, 의미를 결정하는 것은 회수율입니다.

Minas Americas는 원광 품위 분석과 초기 진단 용액 반응을 보고했습니다. 다음 단계에서는 대표성 있는 추출률, 불순물 거동, 물질수지 및 잠재 제품으로 이어지는 경로를 측정합니다.

진단 선별시험이 측정한 것

선정 점토 시료에서 용액 분석까지.

이 선별시험은 1차 침출액의 희토류 농도를 측정하고 대표성 있는 회수율 작업의 출발점을 설정했습니다.

초기 실험실 진단 · 선정된 2025년 구간
SGS ICM694 0.5 M (NH₄)₂SO₄ 초기 pH 4.00 접촉 시간 30분 단일 진단 선별시험
  1. 선정·전처리된 점토 시료 층상 점토 입자와 입자 표면에 표시된 희토류 이온.
    01고체 투입물
    선정 구간 시료

    전처리 및 선별된 실험실 물질. 전체 원광 분석은 고체에 대한 별도 측정입니다.

    원광 분석 매트릭스 · 고체 내 ppm
  2. 단일 완만 조건 실험실 접촉 점토와 황산암모늄 용액이 담긴 실험실 용기에서 희토류 이온이 액체로 들어가는 모습을 표시했습니다.
    02규정 조건
    단일 실험실 접촉

    명시된 한 가지 시험 조건에서 암모늄 이온이 표면 결합 희토류 이온 일부와 교환됩니다.

    진단 시험 · 플랜트 공정도가 아님
  3. 고체 잔류물에서 분리된 1차 침출액 시험은 분석용 액상 1차 침출액과 완전한 물질수지에 필요한 고체 잔류물을 분리합니다.
    03액상 산출물
    1차 침출액

    접촉 후 액체를 PLS로 회수합니다. 이는 시험 용액이며 제품이 아닙니다.

    고체 잔류물 · 완전한 물질수지에 필요
  4. 1차 침출액의 원소 분석 분석 판독값은 1차 침출액 내 희토류 및 기타 원소 농도를 기록합니다.
    04측정 결과
    ICP-MS 용액 분석

    PLS에서 측정된 원소는 MREO 하위 집합을 포함한 산화물 환산 DREO 총량으로 표시됩니다.

    진단 결과 · PLS의 mg/kg
선별시험이 뒷받침하는 것

명시된 조건에서 일부 희토류 원소가 용액으로 들어갔으며, 이는 선정·시험된 시료의 이온흡착 거동을 뒷받침합니다.

확립하지 않는 것

추출률 또는 회수율 백분율, 대표성, 완전한 물질수지, 상업 공정도, 제품 사양 또는 프로젝트 경제성.

선정 진단 선별시험이며 최적화되지 않았습니다. DREO = 탈착 가능 희토류 산화물. MREO = Nd, Pr, Dy 및 Tb 산화물. 출처: SGS 인증서 GQ2509212 및 2025년 10월 21일자 기술 정보 공개. 용액 농도는 회수율이 아닙니다.

선정 천부 진단 침출 결과

Figure 2 · issued English-source graphic and technical context · 6 October 2026

Magnet and heavy rare earths gain share in solution. Four selected 2025 trench intervals and one later auger interval compare original-sample and dissolved-mix MREO and HREO shares. HREO share more than doubles in all five selected diagnostic tests. Composition comparison, not extraction recovery.

Magnet and heavy rare earths gain share in solution. Figure 2 from the 6 October 2026 release: four selected 2025 trench intervals, plus a later auger interval. HREO represented 6.6–12.1% of the dissolved rare-earth mix, compared with 3.0–4.1% in the original samples.

These are composition shares, not extraction recovery or an increase in absolute solution concentration. MREO and HREO overlap through DyTb and must not be added. Selected diagnostic tests are separate from the current SGS bench programme and do not establish an optimised flowsheet or project-wide recovery.

Read the graphic values as a table
Figure 2 · original sample (share of TREO) and dissolved mix (share of DREO)
Selected intervalMREO · originalMREO · dissolvedHREO · originalHREO · dissolvedHREO share multiple
PT-34 · 0–1 m23.7%41.9%3.3%9.3%2.81×
PT-34 · 1–2 m25.3%41.6%4.1%10.9%2.68×
PT-36 · 0–1 m22.2%41.6%3.0%6.6%2.20×
PT-42 · 0–1 m23.8%43.6%3.9%8.2%2.09×
MAV_AD_0002 · 2–3 m (later auger)26.3%48.1%3.6%12.1%3.34×

Later auger interval DyTb share: 0.94% → 2.08%. Shares and multiples use unrounded oxide totals; below-detection values use half the detection limit. SGS ICM694: 0.5 M ammonium sulphate, initial pH 4, 30 minutes. MREO comprises Nd, Pr, Dy and Tb oxides; HREO comprises Y, Dy, Tb, Ho, Er, Tm, Yb and Lu oxides. The graphic panels use different scales.

Diagnostic composition · October source basis

These are the five selected historical diagnostic intervals, not the seven geological samples in the separate SGS bench-scale programme. Values describe desorbed oxide equivalents on the laboratory mg/kg reporting basis—not increased absolute solution concentration or recovery.

October release Table 3 · selected diagnostic intervals · shares use unrounded source totals
IntervalMREO (mg/kg)DREO (mg/kg)MREO share of DREO
PT-34 · 0–1 m16138441.9%
PT-34 · 1–2 m24057841.6%
PT-36 · 0–1 m27866741.6%
PT-42 · 0–1 m16738343.6%
MAV_AD_0002 · 2–3 m23749248.1%

The October source reports PT-34 0–1 m DREO using half detection limits; the reconciled figure is shown above, while the earlier graphic remains unchanged in the dated archive below. MREO and HREO overlap through DyTb and must not be added. Composition is not extraction recovery or commercial process performance.

Historical diagnostic graphic and technical plate · original reporting basis

This is the unchanged earlier illustration, not the October source table or the new SGS bench results. Its original reporting basis must be read in that dated context.

Magnet-Rich in Solution. Five selected shallow SGS diagnostic intervals compared on one common zero-to-700 milligram-per-kilogram scale, with magnet rare-earth oxides highlighted within DREO in solution.
Five selected shallow intervals were tested using the same SGS ICM694 diagnostic method: 0.5 molar ammonium sulphate, nominal pH 4, for 30 minutes. PT-34 from zero to one metre returned 161 milligrams per kilogram MREO in 383 milligrams per kilogram DREO, a 41.9 percent magnet share. PT-34 from one to two metres returned 240 milligrams per kilogram MREO in 578 milligrams per kilogram DREO, a 41.6 percent magnet share. These are two consecutive one-metre intervals from surface. PT-36 from zero to one metre returned 278 milligrams per kilogram MREO in 667 milligrams per kilogram DREO, a 41.6 percent magnet share. PT-42 from zero to one metre returned 167 milligrams per kilogram MREO in 383 milligrams per kilogram DREO, a 43.6 percent magnet share. A later shallow-auger test, MAV_AD_0002 from two to three metres, returned 237 milligrams per kilogram MREO in 492 milligrams per kilogram DREO, a 48.1 percent magnet share. Across the five selected intervals, MREO represented 22.2 to 26.3 percent of TREO in the original samples and 41.6 to 48.1 percent of DREO in solution. This is a composition comparison, not recovery. Each displayed value is a solution concentration, not a recovery percentage. DREO means total desorbable rare-earth oxides expressed as oxide equivalents; MREO comprises the neodymium, praseodymium, dysprosium and terbium oxides. Values are on the laboratory reporting basis. The tests were diagnostic, not optimised, and the results are selected.
Inspect the five selected results and common scale at full resolution.The same selected-result data is provided in accessible HTML in the figure description on this page.
Accessible data transcript (HTML)

Five selected shallow intervals tested using SGS ICM694: 0.5 M ammonium sulphate, nominal pH 4 and 30 minutes.

Magnet rare-earth oxides within DREO in solution
IntervalMREO in solutionDREO in solutionMREO share of DREO
PT-34 · 0-1 m161 mg/kg383 mg/kg41.9%
PT-34 · 1-2 m240 mg/kg578 mg/kg41.6%
PT-36 · 0-1 m278 mg/kg667 mg/kg41.6%
PT-42 · 0-1 m167 mg/kg383 mg/kg43.6%
MAV_AD_0002 · 2-3 m237 mg/kg492 mg/kg48.1%

Selected diagnostic results, not optimised or representative recovery tests. Values are solution concentrations, not recovery percentages. MREO comprises Nd, Pr, Dy and Tb oxides; DREO is expressed on an oxide-equivalent basis.

분석에서 판매 가능성까지

암석에서 매출까지의 서로 다른 다섯 가지 지표.

각 단계는 무엇이 존재하는지부터 무엇을 회수하고 만들고 판매할 수 있는지까지 서로 다른 질문에 답합니다.

  1. 01

    원광 품위

    처리 전 원시료 고체에 함유된 성분. 6월 시추 결과는 원광 품위 분석입니다.

  2. 02

    진단 용액 결과

    명시된 한 가지 실험실 시험에서 용해된 성분. 선정된 2025년 작업은 이 단계에 해당합니다.

  3. 03

    추출률 또는 탈착률

    시료 질량, 용액 부피 및 물질수지로 뒷받침되는, 원래 함유량 중 용액으로 이동한 측정 비율.

  4. 04

    전체 공정 회수율

    손실 및 재순환 스트림을 포함해 각 공정 단계를 거쳐 정의된 제품에 도달하는 비율.

  5. 05

    판매 가능 회수율

    사양, 불순물 및 상업적 공제 후 고객이 대금을 지급할 부분.

원시료 질량, 용액 부피, 고액비 및 완전한 물질수지가 없으면 고체 원광 분석값을 용액 내 mg/kg 농도로 나누어 회수율을 계산할 수 없습니다.

Dated translated context · issued-source chapter through 8 September 2026

공정 스트림

완전한 공정도 구축.

대표성 있는 작업은 원료, 용액, 잔류물, 손실 및 선정 제품화 경로 전반에서 희토류와 불순물을 대조합니다.

실험실의 시료·용액·잔류물 구분을 보여 주는 개념도이며 시험 결과가 아닙니다. 양이나 회수율을 나타내지 않습니다.
준비된 시료용액고체 잔류물

실험실의 시료·용액·잔류물 구분을 보여 주는 개념도이며 시험 결과가 아닙니다. 양이나 회수율을 나타내지 않습니다.

  1. 01
    원광 품위 보고 완료

    원료 물질

    시추 기록과 광물학을 바탕으로 대표성 있는 공정 복합시료를 구축합니다.

  2. 02
    선정 선별시험 보고 완료

    1차 침출액

    명시된 한 가지 황산암모늄 시험 후 희토류 농도를 측정했습니다. 이 반응을 활용해 대표성 있는 회수율 시험을 설계합니다.

  3. 03
    물질수지 필요

    잔류물 및 기타 스트림

    완전한 물질수지를 통해 희토류, 우라늄, 토륨 및 기타 불순물이 어디로 이동하는지 보여야 합니다.

  4. 04
    정의 예정

    잠재 제품

    중간재, 분리 제품 또는 다운스트림 파트너 인터페이스로 이어지는 가장 강력한 경로를 선정합니다.

용액 내 희토류와, 선정 결과 3개 모두에서 실험실 검출한계 미만인 우라늄. PT-36, PT-34 및 PT-42의 정확한 우라늄 및 토륨 농도를 표시합니다.
선정된 2025년 1차 침출액 3개에서 우라늄은 모두 0.04 mg/kg 미만으로 보고되었고, 토륨은 각각 2.59 mg/kg, 0.20 mg/kg 미만 및 2.92 mg/kg으로 보고되었습니다. 선정 구간은 다음과 같습니다. PT-36의 0~1 m 구간은 DREO 667 mg/kg, 우라늄 0.04 mg/kg 미만 및 토륨 2.59 mg/kg; PT-34의 1~2 m 구간은 DREO 578 mg/kg, 우라늄 0.04 mg/kg 미만 및 토륨 0.20 mg/kg 미만; PT-42의 0~1 m 구간은 DREO 383 mg/kg, 우라늄 0.04 mg/kg 미만 및 토륨 2.92 mg/kg입니다. SGS Geosol은 ICM694법(0.5 M 황산암모늄, 초기 pH 4, 30분)을 사용하고 ICP-OES 및 ICP-MS로 측정했습니다. DREO는 산화물 환산 기준이며, 우라늄과 토륨은 원소 농도로 보고됩니다. 미만 기호는 0이 아니라 명시된 실험실 검출한계 미만을 의미합니다. 선정된 진단 용액 결과이며, 자원 평균 또는 대표성 있는 방사선학 데이터셋이 아닙니다. 이 농도는 원료, 잔류물, 용수, 작업장, 잠재 제품 또는 프로젝트 부지 전체의 우라늄이나 토륨을 특성화하지 않으며, 전이, 회수율, 물질수지, 총 방사능, 제품 사양, 환경 안전성 또는 상업적 성과를 확립하지 않습니다.
선정된 U 및 Th 결과 3개를 전체 해상도로 확인하세요.동등한 접근성 HTML 데이터 전문이 바로 아래에 제공됩니다.
접근성 데이터 전문(HTML)

선정된 SGS ICM694 1차 침출액 결과: 0.5 M 황산암모늄, 초기 pH 4, 30분.

선정 구간 3개의 우라늄, 토륨 및 DREO 결과
구간PLS 내 DREO우라늄토륨
PT-36 · 0-1 m667 mg/kg<0.04 mg/kg U2.59 mg/kg Th
PT-34 · 1-2 m578 mg/kg<0.04 mg/kg U<0.20 mg/kg Th
PT-42 · 0-1 m383 mg/kg<0.04 mg/kg U2.92 mg/kg Th

미만 기호는 0이 아니라 SGS 실험실 검출한계 미만을 의미합니다. DREO는 산화물 환산 기준이며 U와 Th는 원소 농도입니다. 선정된 진단 용액 결과이며, 자원 평균 또는 대표성 있는 방사선학 데이터셋이 아닙니다. 이 농도는 원료, 잔류물, 용수, 작업장, 잠재 제품 또는 프로젝트 부지 전체의 우라늄이나 토륨을 특성화하지 않으며, 전이, 회수율, 물질수지, 총 방사능, 제품 사양, 환경 안전성 또는 상업적 성과를 확립하지 않습니다.

방사선학적 증거

완전한 방사선학적 현황 구축.

선정된 2025년 1차 침출액 3개에서 우라늄은 모두 0.04 mg/kg 미만으로 보고되었고, 토륨은 각각 2.59 mg/kg, 0.20 mg/kg 미만 및 2.92 mg/kg으로 보고되었습니다.

다음 단계는 완전한 물질수지 및 적절한 방사선학적 측정과 함께 대표성 있는 원료–용액–잔류물–제품 특성분석을 수행하는 것입니다.

제품화 경로

먼저 제품을 정의한 뒤 고객이 사용할 수 있는지 시험합니다.

신뢰할 수 있는 제품 구상에 앞서 대표성 있는 광물학, 원소별 추출률, 불순물 거동 및 물질수지가 필요합니다.

그 이후에야 Magnes와 잠재 파트너가 정제, 분리, 인증, 실현 가격, 자본 및 운영상 함의를 평가할 수 있습니다.

관련 역량 논의하기

투자 포인트

야금이 투자 논거를 어떻게 바꾸는지 보기.

대표성 있는 회수율, 불순물 및 제품 정의가 지질학적 결과 중 상업적 의미를 가질 수 있는 부분을 결정합니다.

투자 논거를 바꾸는 요인 보기