Current October update · English technical context
La teneur attire l’attention. La récupération détermine si elle compte.
The combined assay compilation covers 879 holes and 7,468.8 assayed metres at the 25 September 2026 cutoff. It includes prior results and complete or partial assay coverage; it is not all-new drilling or gross physical drilling.
MAV_RC_0063 returned 30 metres from surface at 1,853 ppm MREO. Selected cumulative auger profiles include 8 metres at 2,194 ppm MREO in MAV_AD_0691 and 11 metres at 2,179 ppm MREO in MAV_AD_0639.
Reporting of the SGS bench-scale results is the next milestone, after results reconciliation and technical review. No numerical results from this programme are disclosed here. An optimised flowsheet and commercial recovery have not been established; timing and outcomes are not guaranteed.
Older translated project chapters are retained below as dated context, not as the October update. Updated technical translation is not asserted.
Dated translated context · issued-source chapter through 8 September 2026
Minas Americas · Métallurgie et voie potentielle de produit
La teneur attire l’attention. La récupération détermine si elle compte.
Minas Americas a publié des analyses de teneur de tête et une première réponse diagnostique en solution. La prochaine phase mesurera l’extraction représentative, le comportement des impuretés, le bilan massique et la voie vers un produit potentiel.
Ce que le criblage diagnostique a mesuré
De l’échantillon d’argile sélectionné à l’analyse de la solution.
Le criblage a mesuré les concentrations de terres rares dans la solution primaire de lixiviation et établi le point de départ des travaux de récupération représentatifs.
-
01Entrée solideÉchantillon d’intervalle sélectionné
Matériau de laboratoire préparé et criblé. L’analyse de tête totale est une mesure distincte du solide.
Matrice d’analyse de tête · ppm dans le solide -
02Condition définieMise en contact unique en laboratoire
Les ions ammonium s’échangent avec certains ions de terres rares liés à la surface dans une condition d’essai donnée.
Essai diagnostique · pas un schéma de traitement d’usine -
03Sortie liquideSolution primaire de lixiviation
Après la mise en contact, le liquide est recueilli comme PLS. Il s’agit d’une solution d’essai, et non d’un produit.
Résidu solide · requis pour un bilan massique complet -
04Résultat mesuréAnalyse de solution ICP-MS
Les éléments mesurés dans la PLS sont exprimés en totaux DREO équivalents oxydes, y compris le sous-ensemble MREO.
Résultat diagnostique · mg/kg de PLS
Certains éléments de terres rares sont passés en solution dans la condition indiquée, ce qui étaye un comportement d’adsorption ionique dans les échantillons sélectionnés testés.
Pourcentage d’extraction ou de récupération, représentativité, bilan massique complet, schéma de traitement commercial, spécification du produit ou données économiques du projet.
Criblage diagnostique sélectionné ; non optimisé. DREO = oxydes de terres rares désorbables. MREO = oxydes de Nd, Pr, Dy et Tb. Sources : certificat SGS GQ2509212 et information technique datée du 21 octobre 2025. La concentration en solution n’est pas la récupération.
Résultats sélectionnés de lixiviation diagnostique sur des intervalles peu profonds
Figure 2 · issued English-source graphic and technical context · 6 October 2026

Magnet and heavy rare earths gain share in solution. Figure 2 from the 6 October 2026 release: four selected 2025 trench intervals, plus a later auger interval. HREO represented 6.6–12.1% of the dissolved rare-earth mix, compared with 3.0–4.1% in the original samples.
These are composition shares, not extraction recovery or an increase in absolute solution concentration. MREO and HREO overlap through DyTb and must not be added. Selected diagnostic tests are separate from the current SGS bench programme and do not establish an optimised flowsheet or project-wide recovery.
Read the graphic values as a table
| Selected interval | MREO · original | MREO · dissolved | HREO · original | HREO · dissolved | HREO share multiple |
|---|---|---|---|---|---|
| PT-34 · 0–1 m | 23.7% | 41.9% | 3.3% | 9.3% | 2.81× |
| PT-34 · 1–2 m | 25.3% | 41.6% | 4.1% | 10.9% | 2.68× |
| PT-36 · 0–1 m | 22.2% | 41.6% | 3.0% | 6.6% | 2.20× |
| PT-42 · 0–1 m | 23.8% | 43.6% | 3.9% | 8.2% | 2.09× |
| MAV_AD_0002 · 2–3 m (later auger) | 26.3% | 48.1% | 3.6% | 12.1% | 3.34× |
Later auger interval DyTb share: 0.94% → 2.08%. Shares and multiples use unrounded oxide totals; below-detection values use half the detection limit. SGS ICM694: 0.5 M ammonium sulphate, initial pH 4, 30 minutes. MREO comprises Nd, Pr, Dy and Tb oxides; HREO comprises Y, Dy, Tb, Ho, Er, Tm, Yb and Lu oxides. The graphic panels use different scales.
Diagnostic composition · October source basis
These are the five selected historical diagnostic intervals, not the seven geological samples in the separate SGS bench-scale programme. Values describe desorbed oxide equivalents on the laboratory mg/kg reporting basis—not increased absolute solution concentration or recovery.
| Interval | MREO (mg/kg) | DREO (mg/kg) | MREO share of DREO |
|---|---|---|---|
| PT-34 · 0–1 m | 161 | 384 | 41.9% |
| PT-34 · 1–2 m | 240 | 578 | 41.6% |
| PT-36 · 0–1 m | 278 | 667 | 41.6% |
| PT-42 · 0–1 m | 167 | 383 | 43.6% |
| MAV_AD_0002 · 2–3 m | 237 | 492 | 48.1% |
The October source reports PT-34 0–1 m DREO using half detection limits; the reconciled figure is shown above, while the earlier graphic remains unchanged in the dated archive below. MREO and HREO overlap through DyTb and must not be added. Composition is not extraction recovery or commercial process performance.
Historical diagnostic graphic and technical plate · original reporting basis
This is the unchanged earlier illustration, not the October source table or the new SGS bench results. Its original reporting basis must be read in that dated context.

Accessible data transcript (HTML)
Five selected shallow intervals tested using SGS ICM694: 0.5 M ammonium sulphate, nominal pH 4 and 30 minutes.
| Interval | MREO in solution | DREO in solution | MREO share of DREO |
|---|---|---|---|
| PT-34 · 0-1 m | 161 mg/kg | 383 mg/kg | 41.9% |
| PT-34 · 1-2 m | 240 mg/kg | 578 mg/kg | 41.6% |
| PT-36 · 0-1 m | 278 mg/kg | 667 mg/kg | 41.6% |
| PT-42 · 0-1 m | 167 mg/kg | 383 mg/kg | 43.6% |
| MAV_AD_0002 · 2-3 m | 237 mg/kg | 492 mg/kg | 48.1% |
Selected diagnostic results, not optimised or representative recovery tests. Values are solution concentrations, not recovery percentages. MREO comprises Nd, Pr, Dy and Tb oxides; DREO is expressed on an oxide-equivalent basis.
De l’analyse à la valorisation commerciale
Cinq mesures distinctes, de la roche aux revenus.
Chaque étape répond à une question différente, de ce qui est présent à ce qui peut être récupéré, fabriqué et vendu.
- 01
Teneur de tête
Ce que contient l’échantillon solide d’origine avant traitement. Les résultats de forage de juin sont des analyses de teneur de tête.
- 02
Résultat diagnostique en solution
Ce qui s’est dissous lors d’un essai de laboratoire défini. C’est à cette étape que se situent les travaux sélectionnés de 2025.
- 03
Pourcentage d’extraction ou de désorption
La part mesurée du contenu initial transférée en solution, étayée par la masse de l’échantillon, le volume de solution et le bilan massique.
- 04
Récupération du schéma de traitement complet
La part atteignant un produit défini après chaque étape du procédé, y compris les pertes et les flux recyclés.
- 05
Récupération valorisable
La part pour laquelle un client paierait après prise en compte des spécifications, des impuretés et des déductions commerciales.
Une analyse de tête sur solide et une concentration publiée en mg/kg dans une solution ne peuvent être divisées pour calculer la récupération sans la masse initiale de l’échantillon, le volume de solution, le rapport solide-liquide et un bilan massique complet.
Dated translated context · issued-source chapter through 8 September 2026
Flux de procédé
Construire la vue d’ensemble du schéma de traitement.
Les travaux représentatifs rapprocheront les terres rares et les impuretés entre l’alimentation, la solution, les résidus, les pertes et la voie retenue vers un produit.

Compartiments de laboratoire conceptuels, et non résultats d’essais. L’illustration ne donne aucune quantité et ne démontre aucun taux de récupération.
Données radiologiques
Construire le tableau radiologique complet.
Dans trois solutions primaires de lixiviation sélectionnées de 2025, l’uranium était inférieur à 0,04 mg/kg dans chaque résultat ; le thorium était de 2,59 mg/kg, inférieur à 0,20 mg/kg et de 2,92 mg/kg.
L’étape suivante consiste à caractériser de manière représentative l’alimentation, la solution, les résidus et le produit, avec un bilan massique complet et des mesures radiologiques appropriées.
Voie potentielle de produit
Définir d’abord un produit. Tester ensuite si un client peut l’utiliser.
La minéralogie représentative, l’extraction élément par élément, le comportement des impuretés et le bilan massique doivent précéder tout concept de produit robuste.
Ce n’est qu’alors que Magnes et les partenaires potentiels pourront évaluer la purification, la séparation, la qualification, les prix réalisés et les incidences en capital et en exploitation.
Échanger sur une capacité pertinenteThèse d’investissement
Voir comment la métallurgie modifie la thèse.
La récupération représentative, les impuretés et la définition du produit détermineront quelle part du résultat géologique peut avoir une portée commerciale.
Voir ce qui modifie la thèse