Current October update · English technical context
התכולה מושכת תשומת לב. ההשבה קובעת אם היא משמעותית.
The combined assay compilation covers 879 holes and 7,468.8 assayed metres at the 25 September 2026 cutoff. It includes prior results and complete or partial assay coverage; it is not all-new drilling or gross physical drilling.
MAV_RC_0063 returned 30 metres from surface at 1,853 ppm MREO. Selected cumulative auger profiles include 8 metres at 2,194 ppm MREO in MAV_AD_0691 and 11 metres at 2,179 ppm MREO in MAV_AD_0639.
Reporting of the SGS bench-scale results is the next milestone, after results reconciliation and technical review. No numerical results from this programme are disclosed here. An optimised flowsheet and commercial recovery have not been established; timing and outcomes are not guaranteed.
Older translated project chapters are retained below as dated context, not as the October update. Updated technical translation is not asserted.
Dated translated context · issued-source chapter through 8 September 2026
Minas Americas · מטלורגיה ומסלול מוצר
התכולה מושכת תשומת לב. ההשבה קובעת אם היא משמעותית.
Minas Americas דיווחה על בדיקות תכולה לפני עיבוד ועל תגובה ראשונית בתמיסה אבחונית. השלב הבא ימדוד מיצוי מייצג, התנהגות זיהומים, מאזן מסה ואת המסלול למוצר אפשרי.
מה מדדה בדיקת הסינון האבחונית
מדגימת חרסית נבחרת לניתוח תמיסה.
הבדיקה מדדה ריכוזי יסודות אדמה נדירים בתמיסת המיצוי הראשונית וקבעה נקודת פתיחה לעבודת השבה מייצגת.
-
01קלט מוצקדגימת מקטע נבחר
חומר מעבדתי שהוכן ונופה. בדיקת התכולה הכוללת של הדגימה המקורית היא מדידה נפרדת של המוצק.
מטריצת בדיקת ראש · ppm במוצק -
02תנאי מוגדרמגע מעבדתי יחיד
יוני אמוניום מתחלפים עם חלק מיוני יסודות האדמה הנדירים הקשורים לפני השטח בתנאי בדיקה מוגדר אחד.
בדיקה אבחונית · לא תרשים זרימה של מפעל -
03תוצר נוזליתמיסת המיצוי הראשונית
הנוזל לאחר המגע נאסף כ‑PLS. זו תמיסת בדיקה, לא מוצר.
שארית מוצקה · נדרשת למאזן מסה מלא -
04תוצאה נמדדתניתוח תמיסה באמצעות ICP-MS
היסודות הנמדדים ב‑PLS מוצגים כסכומי DREO שווי‑ערך תחמוצתי, לרבות תת‑הקבוצה MREO.
תוצאה אבחונית · מ״ג/ק״ג של PLS
חלק מיסודות האדמה הנדירים עברו לתמיסה בתנאי שצוין, דבר התומך בהתנהגות של ספיחה יונית בדגימות הנבחרות שנבדקו.
אחוז מיצוי או השבה, ייצוגיות, מאזן מסה מלא, תרשים זרימה מסחרי, מפרט מוצר או כלכלת פרויקט.
סקר אבחוני נבחר; לא אופטימלי. DREO = תחמוצות יסודות אדמה נדירים הניתן לספיגה. תחמוצות MREO = Nd, Pr, Dy וTb. מקורות: תעודת SGS GQ2509212 וגילוי טכני מתאריך 21 אוקטובר 2025. ריכוז התמיסה אינו התאוששות.
תוצאות נבחרות של בדיקות מיצוי אבחוניות רדודות
Figure 2 · issued English-source graphic and technical context · 6 October 2026

Magnet and heavy rare earths gain share in solution. Figure 2 from the 6 October 2026 release: four selected 2025 trench intervals, plus a later auger interval. HREO represented 6.6–12.1% of the dissolved rare-earth mix, compared with 3.0–4.1% in the original samples.
These are composition shares, not extraction recovery or an increase in absolute solution concentration. MREO and HREO overlap through DyTb and must not be added. Selected diagnostic tests are separate from the current SGS bench programme and do not establish an optimised flowsheet or project-wide recovery.
Read the graphic values as a table
| Selected interval | MREO · original | MREO · dissolved | HREO · original | HREO · dissolved | HREO share multiple |
|---|---|---|---|---|---|
| PT-34 · 0–1 m | 23.7% | 41.9% | 3.3% | 9.3% | 2.81× |
| PT-34 · 1–2 m | 25.3% | 41.6% | 4.1% | 10.9% | 2.68× |
| PT-36 · 0–1 m | 22.2% | 41.6% | 3.0% | 6.6% | 2.20× |
| PT-42 · 0–1 m | 23.8% | 43.6% | 3.9% | 8.2% | 2.09× |
| MAV_AD_0002 · 2–3 m (later auger) | 26.3% | 48.1% | 3.6% | 12.1% | 3.34× |
Later auger interval DyTb share: 0.94% → 2.08%. Shares and multiples use unrounded oxide totals; below-detection values use half the detection limit. SGS ICM694: 0.5 M ammonium sulphate, initial pH 4, 30 minutes. MREO comprises Nd, Pr, Dy and Tb oxides; HREO comprises Y, Dy, Tb, Ho, Er, Tm, Yb and Lu oxides. The graphic panels use different scales.
Diagnostic composition · October source basis
These are the five selected historical diagnostic intervals, not the seven geological samples in the separate SGS bench-scale programme. Values describe desorbed oxide equivalents on the laboratory mg/kg reporting basis—not increased absolute solution concentration or recovery.
| Interval | MREO (mg/kg) | DREO (mg/kg) | MREO share of DREO |
|---|---|---|---|
| PT-34 · 0–1 m | 161 | 384 | 41.9% |
| PT-34 · 1–2 m | 240 | 578 | 41.6% |
| PT-36 · 0–1 m | 278 | 667 | 41.6% |
| PT-42 · 0–1 m | 167 | 383 | 43.6% |
| MAV_AD_0002 · 2–3 m | 237 | 492 | 48.1% |
The October source reports PT-34 0–1 m DREO using half detection limits; the reconciled figure is shown above, while the earlier graphic remains unchanged in the dated archive below. MREO and HREO overlap through DyTb and must not be added. Composition is not extraction recovery or commercial process performance.
Historical diagnostic graphic and technical plate · original reporting basis
This is the unchanged earlier illustration, not the October source table or the new SGS bench results. Its original reporting basis must be read in that dated context.

Accessible data transcript (HTML)
Five selected shallow intervals tested using SGS ICM694: 0.5 M ammonium sulphate, nominal pH 4 and 30 minutes.
| Interval | MREO in solution | DREO in solution | MREO share of DREO |
|---|---|---|---|
| PT-34 · 0-1 m | 161 mg/kg | 383 mg/kg | 41.9% |
| PT-34 · 1-2 m | 240 mg/kg | 578 mg/kg | 41.6% |
| PT-36 · 0-1 m | 278 mg/kg | 667 mg/kg | 41.6% |
| PT-42 · 0-1 m | 167 mg/kg | 383 mg/kg | 43.6% |
| MAV_AD_0002 · 2-3 m | 237 mg/kg | 492 mg/kg | 48.1% |
Selected diagnostic results, not optimised or representative recovery tests. Values are solution concentrations, not recovery percentages. MREO comprises Nd, Pr, Dy and Tb oxides; DREO is expressed on an oxide-equivalent basis.
מבדיקה ועד לשיעור בר‑תשלום
חמישה מדדים נפרדים מהסלע ועד להכנסה.
כל שלב עונה על שאלה אחרת, ממה שנמצא ועד למה שניתן להשיב, לייצר ולמכור.
- 01
תכולה בדגימה לפני עיבוד
מה מכילה הדגימה המוצקה המקורית לפני עיבוד. תוצאות קידוחי יוני הן בדיקות תכולה לפני עיבוד.
- 02
תוצאת תמיסה אבחונית
מה שנמס בבדיקה מעבדתית מוגדרת אחת. זהו השלב שבו נמצאת העבודה הנבחרת מ‑2025.
- 03
אחוז מיצוי או דה‑ספיחה
החלק הנמדד מן המלאי המקורי שעבר לתמיסה, בהתבסס על מסת הדגימה, נפח התמיסה ומאזן מסה.
- 04
השבה מלאה בתרשים הזרימה
החלק שמגיע למוצר מוגדר לאחר כל שלב בתהליך, לרבות הפסדים וזרמי מחזור.
- 05
השבה בת‑תשלום
החלק שעבורו לקוח ישלם לאחר התחשבות במפרטים, זיהומים וניכויים מסחריים.
לא ניתן לחלק בדיקת תכולה של מוצק בריכוז המדווח במ״ג/ק״ג בתמיסה כדי לחשב השבה, ללא מסת הדגימה המקורית, נפח התמיסה, יחס מוצקים‑לנוזל ומאזן מסה מלא.
Dated translated context · issued-source chapter through 8 September 2026
זרמי התהליך
בניית התמונה המלאה של תרשים הזרימה.
עבודה מייצגת תאזן את יסודות האדמה הנדירים והזיהומים בין חומר ההזנה, התמיסה, השארית, ההפסדים ומסלול המוצר הנבחר.

המחשה מושגית של חלקי ניסוי נפרדים, ולא תוצאות בדיקה. האיור אינו מציג כמויות ואינו מוכיח שיעור השבה.
ראיות רדיולוגיות
בנה את התמונה הרדיולוגית השלמה.
בשלוש תמיסות מיצוי ראשוניות נבחרות מ‑2025, אורניום דווח מתחת ל‑0.04 מ״ג/ק״ג בכל התוצאות; תוריום דווח ברמות של 2.59 מ״ג/ק״ג, מתחת ל‑0.20 מ״ג/ק״ג ו‑2.92 מ״ג/ק״ג.
השלב הבא הוא אפיון הזנה-תמיסה-שיירי-מוצר מייצג עם מאזן מסה מלא ומדידות רדיולוגיות מתאימות.
מסלול המוצר
ראשית הגדירו מוצר. לאחר מכן בדוק אם לקוח יכול להשתמש בו.
מינרלוגיה ייצוגית, מיצוי יסוד אחר יסוד, התנהגות טומאה ו-מאזן מסה חייבות לבוא לפני מושג מוצר בר הגנה.
רק אז יכולים Magnes ושותפים פוטנציאליים להעריך טיהור, הפרדה, הסמכה, תמחור מומש, הון ומשמעות תפעולית.
דון ביכולת רלוונטיתמקרה השקעה
ראה כיצד מטלורגיה משנה את התזה.
השבה מייצגת, זיהומים והגדרת המוצר יקבעו כמה מהתוצאה הגיאולוגית יכולה להיות חשובה מבחינה מסחרית.
ראה מה משנה את התזה